<LOGO>
FM Transmitter Measurement Report
Created: 2026-11-05 21-32-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 51 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.7 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 65 kHz 18719 0,6090
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,4 dBr 3,85 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 21:32, 5.11.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 65 kHz MIN: 12 kHz % above 76 kHz: 0,6090 Acquired: 2026.11.05 21.31.40 Total samples: 18719 Equivalent time: 0:15:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,3 dBr MIN: 0,4 dBr AVE: 3,85 dBr % above 12,2 dBr: 0,0 Last value: 3,3 dBr (2026.11.05 21.31.40) 21.18 21.20 21.22 21.24 21.26 21.28 21.30 0 2 4 6 Pm [dBr]